Verification and Validation Planning for Medical Software

How to plan V&V for regulated software — test strategy, traceability, clinical scenarios, and release evidence.

Verification vs. validation — and why both matter

Verification asks: did we build the software correctly against specifications? Validation asks: does the software meet user needs and intended use in real or simulated clinical conditions? Regulated submissions require both, with traceable evidence.

Poor V&V planning is one of the most common causes of delayed releases, audit findings, and expensive rework in medical software programmes.

Building the test strategy

A test strategy document aligns the team on scope, environments, responsibilities, and acceptance criteria before test execution begins.

  • Test levels defined: unit, integration, system, regression, acceptance.
  • Entry and exit criteria for each test phase documented.
  • Test environment parity with production (OS, integrations, load).
  • Responsibility matrix: dev, QA, independent V&V, clinical evaluator.
  • Defect severity classification and release blocking rules.

Traceability-driven test design

Every requirement worth shipping should have at least one test that proves it — and high-risk requirements should have several.

  • Requirements traceability matrix links IDs to test case IDs.
  • Risk controls with software mitigation have explicit test coverage.
  • Boundary and negative tests included, not only happy path.
  • Regression suite automated where feasible for core safety functions.
  • Test results stored with version, environment, and approver metadata.

Clinical scenario testing

Medical software must be validated against how clinicians actually work — not only against technical specs.

  • Clinical use scenarios derived from intended use and user needs.
  • Simulated workflows include interruptions, handoffs, and concurrent users.
  • Alarm and alert pathways tested for timeliness and clarity.
  • Integration tests use realistic HL7/FHIR messages or device data feeds.
  • Usability observations captured during validation sessions.

Independent V&V

Independent verification — by a team not responsible for building the feature — strengthens credibility with regulators and hospital customers.

For connected products integrating with hospital systems, independent V&V should include interface testing, data integrity checks across system boundaries, and regression on every release candidate.

Release evidence package

The goal of V&V is a defensible release decision. Package evidence so reviewers can follow the thread from claim to proof.

  • V&V summary report with pass/fail statistics and open issues.
  • Traceability matrix export showing coverage completeness.
  • Known anomalies documented with risk acceptance rationale.
  • Release checklist signed by engineering and quality.
← Back to resources Discuss your project
Lone Shepherd Systems Lone Shepherd Systems

We help regulated medical product teams design, build, validate, secure, and launch connected medical technologies with engineering, quality, usability, safety, cybersecurity, and regulatory-readiness support.

1309 Coffeen Avenue STE 1200
Sheridan, WY 82801
United States

Services

  • Regulated Product Strategy
  • Connected Device Software
  • SaMD Engineering
  • Verification & Validation
  • Quality System Readiness
  • Regulatory Pathway Support

Industries

  • Medical Device Startups
  • Digital Health
  • Biosensors & Wearables
  • Diagnostics
  • SaMD Teams
  • Combination Products

Resources

  • Resources
  • FAQ
  • Privacy Policy
  • Contact

© 2026 Lone Shepherd Systems. All rights reserved.

Information on this website is for general consulting-service communication only. Regulatory requirements vary by product, claim, market, and risk profile.